Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)

Product Details
Customization: Available
Membrane Type: Hollow
Type: UF
Gold Member Since 2021

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (19)
  • Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)
  • Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)
  • Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)
  • Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)
  • Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)
  • Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)
Find Similar Products

Basic Info.

Model NO.
UF4040/UF4046/8040/8060/2860
Material
Pan PVDF
Size
UF4040(PP)
Colour
White
Warranty
12 Months
Brand
Frotec or Customized
Transport Package
Carton
Specification
UF4040(PAN)
Trademark
FROTEC
Origin
China
HS Code
8421999090
Production Capacity
5000PCS\Month

Product Description

Hollow Fiber Membrane UF Module
1. Tech Data of Membrane Materials
Type: UF4040(PP)


 
4. Reference
No
Notice
1 If the membrane have be treated with hydrophilic property in dry condition, there will be
activated-agent on the membrane. Please clean the membrane by water to remove the
possible chemical agent for 30mins. The activated agent is harmless for health.
2 If the membrane have be treated with hydrophilic property in wet condition, there will
be protective water in the module. Maybe disinfection Chemical agent will be used.
Please clean the membrane by water to remove the possible chemicals for 10 mins.
3 The PP membrane have excellent properties to resist the chemicals of acid, alkaline
(HCl or NaOH) and others, but not strong enough in high concentration oxidiztive
chemicals (NaClO). Please do not keep the membren in such chemical for long time.
4 During the cross-flow and filtration, the bigger flowrate can increase the filtration and
resist the fouling of the membrane.
5 The temperature will greatly influence the UF filtration, the effluent rate will be
decreased with the lower temperature.
6 During the chemical washing, you can submerged the membren in the chemicals or
cycle the chemicals in the module for hours.
7 After the membrane has been used, please keep the membrane in wet condition all the
time. If the membrane become dry, the filtration ability will be lost.


 
6. Connection mode of the UF module
The UF module is outside-to-inside filtration one. There will be an "arrow" stick in the casing
of modules. On the counter side of the arrow direction, it is feed-in port. On the arrow direction,
the center port is "concentration" port, and the side port is "clean water" out port.
Hear we list two flushing ways:
The simple flushing: The flushing water will be pumped from "concentration" out port to
"feed-in" port. The effluent rate can be recovered slightly maybe.
The back-flushing: The flushing water will be pumped from the "clean water" out-port to the
"fedd-in" port. The effluent rate can be recovered greatly.But the flushing water must be clean
water or UF water.
The UF modules can be installed in horizontal direction or vertical direction.


 
Two or more UF modules can be used together to get more capacity of filtration. If the flushing
and air/water flushing can be done automatically, the UF modules can be keep a better filtration
for a long time.

FROTEC ULTRA FILTRATION MEMBRANE

   Ultra-filtration is an advanced technology to separate, purify and concentrate substance . It presents hollow capillary tube shape or hollow fiber shape, micro-pore covers tube wall densely. Feed liquid is flowing in or out the membrane under the influence of pressure, dissolvent or small molecule can permeate membrane and become pure liquid by collection, while large molecule (such as  protein, each kind of enzyme, nucleic acid, polysaccharide and so on) ,colloid particle (such as emulsion, micro-ion) and bacterium are cut off by the membrane and are taken off by the circulating liquid flow to become concentrating liquid.
FROTEC ULTRA FILTRATION MEMBRANE 4040
 
Product Code Module Type A (mm) B (mm) C (mm) L1(mm)
UF-4040 UF-4040 101 19 27 1016



FROTEC ULTRA FILTRATION MEMBRANE 4046

 
Product Code Module Type A (mm) B (mm) C (mm) L1(mm) L2(mm)
UF-4046 UF-4046 169 113 112.5 965 1155

FROTEC ULTRA FILTRATION MEMBRANE 6060
 
Product Code Module Type A (mm) B (mm) C (mm) L1(mm) L2(mm)
UF-6060 UF-6060 195 160 160 1132 1352

FROTEC ULTRA FILTRATION MEMBRANE 8060
 
Product Code Module Type A (mm) B (mm) C (mm) L1(mm) L2(mm)
UF-8060 UF-8060 320 237 183.5 1020 1415
FROTEC ULTRA FILTRATION MEMBRANE 1060
 
Product Code Module Type A (mm) B (mm) C (mm) L1(mm) L2(mm)
UF-1060 UF-1060 323 303 173 1600 1713


Ultrafiltration membrane module parameters
Module UF-4040 UF-4046 UF-6060 UF-8060 UF-1060
Module type Inside-out Inside-out Inside-out Inside-out Inside-out
Shell  and seal materials PVC,epoxy resins PVC,epoxy resins PVC,epoxy resins PVC,epoxy resins PVC,epoxy resins
Membrane Material PAN/PVC PAN/PVC PAN/PVC PAN/PVC PAN/PVC
Molecular Weight Cut off(Dalton) 50.000 50.000 100.000 100.000 100.000
Size (mm) Ø90×1016 Ø90×1155 Ø160×1352 Ø200×1415 Ø250×1713
Effective membrane  area 4m2 4.8m2 15m2 25m2 52m2
Hollow fiber id/od size 1.0mm/1.6mm 1.0mm/1.6mm 1.0mm/1.6mm 1.0mm/1.6mm 1.0mm/1.6mm
Max operating pressure 0.3Mpa 0.3Mpa 0.3Mpa 0.3Mpa 0.3Mpa
Suggest operating pressure <0.2Mpa <0.2Mpa <0.2Mpa <0.2Mpa <0.2Mpa
Max transmembrane pressure <0.2Mpa <0.2Mpa <0.2Mpa <0.2Mpa <0.2Mpa
Backwash pressure 0.05-0.1Mpa 0.05-0.1Mpa 0.05-0.1Mpa 0.05-0.1Mpa 0.05-0.1Mpa
Produced water pollution index( SDI 25) <3 <3 <1 <3 <3
Initial flux 0.8m3/h 1.0m3/h 4.5m3/h 5m3/h 9m3/h
Design flux 40-150L/m2/h 40-150L/m2/h 40-150L/m2/h 40-150L/m2/h 40-150L/m2/h
Operating mode Cross flow or dead-end flow Cross flow or dead-end flow Cross flow or dead-end flow Cross flow or dead-end flow Cross flow or dead-end flow
Bacteria removal rate >4log >4log >6log >6log >6log
Permeate turbidity <0.1NTU <0.1NTU <0.1NTU <0.1NTU <0.1NTU
Operating temperature 5~40ºC 5~40ºC 5~40ºC 5~40ºC 5~40ºC
PH range 2~10 2~10 2~10 2~10 2~10



FROTEC ULTRA FILTRATION MEMBRANE 2860  2880


UF2860 UF 2880 are an Ultra Filtration membrane module made by PVDF material hollow fiber tubes, and cover is PVC shell. These UF membranes are characterized by Antibacterial function.(especially good for removing particulate, virus, colloid, albumin protein, gelatin, carbon black, organic compound.......)


 




UF2880

 
Filtration Type Outside-In
 
Max. Working Pressure (@ 20ºC)
 
94 psi (0.62MPa / 6.25bar)
Suggested Working Pressure 43 psi (0.3MPa / 3bar)
Backwash pressure(suggested) 36 psi (0.25Mpa /2.5bar )
Air Flush Rate(Duration 2~4mins)(suggested) 7~9 acfm (12~15m3/h)
Max. Trans-Membrane Pressure Drop(TMP) 30 psi (0.2MPa / 2bar)
Feed Water Temperature 1~40ºC
Active Membrane Area 77 m2(829ft2)
Filtrate Water Flow Range 13~40 GPM (3~9M3PH)
Molecular Weight Cut-Off /MWCO/(average porosity/pore Ø) 100,000 Dalton (0.01µm~0.1 µm)
Hollow Fiber Tubes In/Out Diameter 0.6/1.2mm
pH Range of Feed Water During Continuous Operation 2~11
Operation Mode Cross flow/Dead-end flow
Max Feed Water Turbidity < 300 NTU
Product Water Turbidity <0. 1 NTU
Feed Water Particle size (max.)
 
< 300 µ
 
Feed Water SDI15 < 25
Product Water SDI15 < 2.5
Product water average flow in system(Suggested) Approximately 3M3PH







UUF2860
Filtration Type Outside-In
 
Max. Working Pressure (@ 20ºC)
 
94 psi (0.62MPa / 6.25bar)
Suggested Working Pressure 43 psi (0.3MPa / 3bar)
Backwash pressure(suggested) 36 psi (0.25Mpa /2.5bar )
Air Flush Rate(Duration 2~4mins)(suggested) 7~9 acfm (12~15m3/h)
Max. Trans-Membrane Pressure Drop(TMP) 30 psi (0.2MPa / 2bar)
Feed Water Temperature 1~40ºC
Active Membrane Area 55 m2(592ft2)
Filtrate Water Flow Range 9~27 GPM (2~6M3PH)
Molecular Weight Cut-Off /MWCO/(average porosity/pore Ø) 100,000 Dalton (0.01µm~0.1 µm)
Hollow Fiber Tubes In/Out Diameter 0.6/1.2mm
pH Range of Feed Water During Continuous Operation 2~11
Operation Mode Cross flow/Dead-end flow
Max Feed Water Turbidity < 300 NTU
Product Water Turbidity <0. 1 NTU
Feed Water Particle size (max.)
 
< 300 µ
 
Feed Water SDI15 < 25
Product Water SDI15 < 2.5
Product water average flow in system(Suggested) Approximately 2.5M3PH



 
MODEL L L1 L2 L3 D  In/out Ø
UF2860 1860 mm (73'')





 
1500 mm (59'')
 
1630mm (64'') 1820 mm (72'') 225mm (9'') DN50 mm (2'')
UF2880 2360 mm (93'')





 
2000 mm (79'')
 
2130mm (84'') 2320 mm (91'') 225mm (9'') DN50 mm (2'')



Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)Manufacturers of Hollow Fiber Ultrafiltration Membranes Used in Water Treatment Plants UF4040 (PAN)



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier