Ultra-filtration is an advanced technology to separate, purify and concentrate substance . It presents hollow capillary tube shape or hollow fiber shape, micro-pore covers tube wall densely. Feed liquid is flowing in or out the membrane under the influence of pressure, dissolvent or small molecule can permeate membrane and become pure liquid by collection, while large molecule (such as  protein, each kind of enzyme, nucleic acid, polysaccharide and so on) ,colloid particle (such as emulsion, micro-ion) and bacterium are cut off by the membrane and are taken off by the circulating liquid flow to become concentrating liquid.

FROTEC ULTRA FILTRATION MEMBRANE 4040             
Product Code Module Type A (mm) B (mm) C (mm) L1(mm)
UF-4040 UF-4040 101 19 27 1016





FROTEC ULTRA FILTRATION MEMBRANE 4046



Product Code Module Type A (mm) B (mm) C (mm) L1(mm) L2(mm)
UF-4046 UF-4046 169 113 112.5 965 1155


FROTEC ULTRA FILTRATION MEMBRANE 6060

Product Code Module Type A (mm) B (mm) C (mm) L1(mm) L2(mm)
UF-6060 UF-6060 195 160 160 1132 1352
FROTEC ULTRA FILTRATION MEMBRANE 8060

 
Product Code Module Type A (mm) B (mm) C (mm) L1(mm) L2(mm)
UF-8060 UF-8060 320 237 183.5 1020 1415


FROTEC ULTRA FILTRATION MEMBRANE 1060

Product Code Module Type A (mm) B (mm) C (mm) L1(mm) L2(mm)
UF-1060 UF-1060 323 303 173 1600 1713































Ultrafiltration membrane module parameters
 
Module UF-4040 UF-4046 UF-6060 UF-8060 UF-1060
Module type Inside-out Inside-out Inside-out Inside-out Inside-out
Shell  and seal materials PVC,epoxy resins PVC,epoxy resins PVC,epoxy resins PVC,epoxy resins PVC,epoxy resins
Membrane Material PAN/PVC PAN/PVC PAN/PVC PAN/PVC PAN/PVC
Molecular Weight Cut off(Dalton) 50.000 50.000 100.000 100.000 100.000
Size (mm) Ø90×1016 Ø90×1155 Ø160×1352 Ø200×1415 Ø250×1713
Effective membrane  area 4m2 4.8m2 15m2 25m2 52m2
Hollow fiber id/od size 1.0mm/1.6mm 1.0mm/1.6mm 1.0mm/1.6mm 1.0mm/1.6mm 1.0mm/1.6mm
Max operating pressure 0.3Mpa 0.3Mpa 0.3Mpa 0.3Mpa 0.3Mpa
Suggest operating pressure <0.2Mpa <0.2Mpa <0.2Mpa <0.2Mpa <0.2Mpa
Max transmembrane pressure <0.2Mpa <0.2Mpa <0.2Mpa <0.2Mpa <0.2Mpa
Backwash pressure 0.05-0.1Mpa 0.05-0.1Mpa 0.05-0.1Mpa 0.05-0.1Mpa 0.05-0.1Mpa
Produced water pollution index( SDI 25) <3 <3 <1 <3 <3
Initial flux 0.8m3/h 1.0m3/h 4.5m3/h 5m3/h 9m3/h
Design flux 40-150L/m2/h 40-150L/m2/h 40-150L/m2/h 40-150L/m2/h 40-150L/m2/h
Operating mode Cross flow or dead-end flow Cross flow or dead-end flow Cross flow or dead-end flow Cross flow or dead-end flow Cross flow or dead-end flow
Bacteria removal rate >4log >4log >6log >6log >6log
Permeate turbidity <0.1NTU <0.1NTU <0.1NTU <0.1NTU <0.1NTU
Operating temperature 5~40ºC 5~40ºC 5~40ºC 5~40ºC 5~40ºC
PH range 2~10 2~10 2~10 2~10 2~10




























FROTEC ULTRA FILTRATION MEMBRANE 2860  2880


UF2860 UF 2880 are an Ultra Filtration membrane module made by PVDF material hollow fiber tubes, and cover is PVC shell. These UF membranes are characterized by Antibacterial function.(especially good for removing particulate, virus, colloid, albumin protein, gelatin, carbon black, organic compound.......)


 




UF2880

 
Filtration Type Outside-In
 
Max. Working Pressure (@ 20ºC)
 
94 psi (0.62MPa / 6.25bar)
Suggested Working Pressure 43 psi (0.3MPa / 3bar)
Backwash pressure(suggested) 36 psi (0.25Mpa /2.5bar )
Air Flush Rate(Duration 2~4mins)(suggested) 7~9 acfm (12~15m3/h)
Max. Trans-Membrane Pressure Drop(TMP) 30 psi (0.2MPa / 2bar)
Feed Water Temperature 1~40ºC
Active Membrane Area 77 m2(829ft2)
Filtrate Water Flow Range 13~40 GPM (3~9M3PH)
Molecular Weight Cut-Off /MWCO/(average porosity/pore Ø) 100,000 Dalton (0.01µm~0.1 µm)
Hollow Fiber Tubes In/Out Diameter 0.6/1.2mm
pH Range of Feed Water During Continuous Operation 2~11
Operation Mode Cross flow/Dead-end flow
Max Feed Water Turbidity < 300 NTU
Product Water Turbidity <0. 1 NTU
Feed Water Particle size (max.)
 
< 300 µ
 
Feed Water SDI15 < 25
Product Water SDI15 < 2.5
Product water average flow in system(Suggested) Approximately 3M3PH







UUF2860
Filtration Type Outside-In
 
Max. Working Pressure (@ 20ºC)
 
94 psi (0.62MPa / 6.25bar)
Suggested Working Pressure 43 psi (0.3MPa / 3bar)
Backwash pressure(suggested) 36 psi (0.25Mpa /2.5bar )
Air Flush Rate(Duration 2~4mins)(suggested) 7~9 acfm (12~15m3/h)
Max. Trans-Membrane Pressure Drop(TMP) 30 psi (0.2MPa / 2bar)
Feed Water Temperature 1~40ºC
Active Membrane Area 55 m2(592ft2)
Filtrate Water Flow Range 9~27 GPM (2~6M3PH)
Molecular Weight Cut-Off /MWCO/(average porosity/pore Ø) 100,000 Dalton (0.01µm~0.1 µm)
Hollow Fiber Tubes In/Out Diameter 0.6/1.2mm
pH Range of Feed Water During Continuous Operation 2~11
Operation Mode Cross flow/Dead-end flow
Max Feed Water Turbidity < 300 NTU
Product Water Turbidity <0. 1 NTU
Feed Water Particle size (max.)
 
< 300 µ
 
Feed Water SDI15 < 25
Product Water SDI15 < 2.5
Product water average flow in system(Suggested) Approximately 2.5M3PH



 
MODEL L L1 L2 L3 D  In/out Ø
UF2860 1860 mm (73'')





 
1500 mm (59'')
 
1630mm (64'') 1820 mm (72'') 225mm (9'') DN50 mm (2'')
UF2880 2360 mm (93'')





 
2000 mm (79'')
 
2130mm (84'') 2320 mm (91'') 225mm (9'') DN50 mm (2'')

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier